Section 206.6.1 covers scoping requirements in the most current ADA Standards for accessible routes existing elevators.
Search Results "Elevator"
-
Existing Elevators: ADA Standard Section 206.6.1
-
407 Elevators
-
407.1 General
Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger elevators as classified by ASME A17.1....
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
407.2.1.2 Size
EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
407.2.1.5 Signals
Destination-oriented elevators shall not be required to comply with 407.2.1.5 provided that visible and audible signals complying with 407.2.2 indicating which elevator car to enter are...
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car...
-
407.2.2.2 Visible Signals
Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
-
407.2.2.3 Audible Signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
407.3.6 Width
The width of elevator doors shall comply with Table 407.4.1....
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....
-
407.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (13 mm) under rated loading...
-
407.4.6 Elevator Car Controls
Where provided, elevator car controls shall comply with 407.4.6 and 309.4....
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
407.4.7.1.2 Location
Raised character and braille designations shall be placed immediately to the left of the control button to which the designations apply. EXCEPTION: Where space on an existing car...
-
408.4 Elevator Cars
Elevator cars shall comply with 408.4....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....