(2) Ramp surface. The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear...
Search Results "Commuter Authority"
Commonly Searched Documents
-
§ 38.95(c)(2) Ramp surface
-
§ 38.95(d) Mobility aid seating location
(d) Mobility aid seating location. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches. Such...
-
§ 38.95(a)(2) Exception
(2) Exception. If level-entry boarding, portable or platform lifts, ramps or bridge plates meeting the applicable requirements of this section are provided on station platforms or...
-
§ 38.95(c)(3) Ramp threshold
(3) Ramp threshold. The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge...
-
§ 38.93(d)(3) Exception
(3) Exception. Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts...
-
4.1.6(3)(d)
(d) In making the determination as to what constitutes "substantial alteration," the agency issuing standards for the facility shall consider the total cost of all alterations...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
-
§ 38.95(b)(13) Handrails
(13) Handrails. Platforms on lifts shall be equipped with handrails, on two sides, which move in tandem with the lift which shall be graspable and provide support to standees...
-
§ 37.33 Airport transportation systems
[See subsections ...]
-
§ 37.93 One car per train rule
[See subsections ...]
-
§ 38.93(d)(4) Exception
(4) Exception. Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of...
-
§ 38.95(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches,...
-
§ 37.42 Service in an Integrated Setting to Passengers at Intercity, Commuter, and High-Speed Rail Station Platforms Constructed or Altered After February 1, 2012
[See subsections ...]
-
§ 37.42 Service in an Integrated Setting to Passengers at Intercity, Commuter, and High-Speed Rail Station Platforms Constructed or Altered After February 1, 2012
[76 FR 57935, Sept. 19, 2011]
-
604.5.2 Rear Wall
Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
-
604.5.2 Rear Wall
Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
-
604.5.2 Rear Wall
Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
- Figure 604.5.2 Rear Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
-
604.5.2 Rear Wall
Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
-
DOT’s ADA Regulations
They apply to any public entity that provides public transportation or intercity or commuter rail transportation, as well as to any private entity that provides public transportation or...
- Public transport. Fixed ramp solution for trains provides wheelchair access, Stepless by Guldmann
-
ADA & Level Boarding – Accessibility Standards Applying to Passenger Rail Cars
49 CFR §§ 27.7(a), 37.5(a), 49 CFR Part 38 December 4, 2012
-
§ 38.107(a)(4)
(4) Faucets and flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls shall...
-
For a new public building, if EV charging equipment is not installed at this time, what is the extent of the infrastructure that an installer is required to show for plan check review?
RESPONSE: Plans and specifications must accurately describe the full extent of the work to be performed. Some enforcement jurisdictions (primarily city- and county building...