In cases where a physical alteration to an historic property is not required because of §8.21(c)(1)(ii) or (iii), alternative methods of achieving program accessibility include using audio-visual...
Search Results "Alternate Format"
-
§8.21(c)(2)(ii) Historic preservation programs or activities
-
Toilet Stalls [4.17]
The alternate stalls shown in Figure 30(b) can never satisfy new construction accessibility requirements....
- NetCentric Technologies Inc. CommonLook PDF Validator Software
-
1134A.6, Item 1.3
1.3 Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a...
-
Shower Stalls [4.21]
Shower Stalls [4.21] In accessible bathing facilities, at least one tub or one shower must be accessible. ADAAG provides specifications for several types of shower stall designs:...
-
1134A.6, Item 1.3
1.3. Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall...
-
§ 37.7 Standards for accessible vehicles
[56 FR 45621, Sept. 6, 1991, as amended at 58 FR 63101, Nov. 30, 1993; 61 FR 25416, May 21, 1996]
-
Note Regarding Comparative Table
For the convenience of the reader, the Appendix to this document provides a table that lists in column one the exceptions contained in the document and in the second column, the UFAS...
- Creating Forms in Nuance Power PDF
- Creating PDF Documents from Multiple Files with Nuance Power PDF
- Gain control of your PDF workflows with Nuance Power PDF
- Document Assembly with Nuance Power PDF
- Creating PDFs from Word with Nuance Power PDF
- Power PDF and Electronic Signatures
- Create a table of contents from any PDF file
- Document Conversion to Word with Nuance Power PDF
- Nuance Power PDF with RMS Security
- Document Conversion to Excel with Nuance Power PDF
-
Guest Rooms with Mobility Features: ADA Standard Section 224.2
Section 224.2 covers scoping requirements in the current ADA Standards for transient lodging guest rooms with mobility features.
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following: A transfer type shower...
-
19. Q: Does the ADA require all police stations to be accessible to people with disabilities?
In some situations, however, it may be as effective to use alternative methods, such as relocating a service to an accessible building, or providing an officer who goes directly to the individual...
-
11B-610.3 Shower compartment seats
A seat in an alternate roll-in type shower compartment shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall...
-
11B-610.3 Shower compartment seats
A seat in an alternate roll-in type shower compartment shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall...