Toilet stall doors shall comply with 4.13....
Search Results "Toilet Room Signage"
-
4.17.5* DOORS
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-224.1 General
Hotels, motels, inns, dormitories, resorts and similar transient lodging facilities shall provide guest rooms in accordance with Sections 11B-224.1 through 11B-224.6....
-
11B-223.2.2 Facilities specializing in treating conditions that affect mobility
In facilities specializing in treating conditions that affect mobility, 100 percent of the patient sleeping rooms shall provide mobility features complying with 805....
-
11B-223.2.2 Facilities specializing in treating conditions that affect mobility
In facilities specializing in treating conditions that affect mobility, 100 percent of the patient sleeping rooms shall provide mobility features complying with 805....
- ASI Global Partitions Stainless Steel Toilet Partitions
-
4.17.5* Doors
Toilet stall doors, including door hardware, shall comply with 4.13....
-
703.3 Braille
703.3 Braille. Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ...
-
TACTILE SIGN
TACTILE SIGN. A sign containing raised characters and/or symbols and accompanying Braille.
-
Signs
Signs. Section 216.10 of the 2010 Standards requires each covered assembly area to provide signs at each auditorium to inform patrons that assistive listening systems are available....
-
703.6.1 Pictogram Field
703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. Figure...
-
11B-216.13 Cleaner Air Symbol
[See subsections ...]
-
11B-703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with Sections 11B-703.3 and 11B-703.4. Advisory 11B-703.3 Braille. Contracted Braille uses special characters called...
-
703.2 Raised Characters
Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4. Advisory 703.2...
-
703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. Figure 703.6.1 Pictogram Field
-
703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
-
703.7.2.4 Assistive Listening Systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4.
-
R211.1 General
R211.1 General. Signs shall comply with R211. Where audible sign systems and other technologies are used to provide information equivalent to the information contained on pedestrian...
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
T702.7 Line Spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
T702.3 Character Proportions
Characters shall use fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.