11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...
Search Results "Single User Toilet Room"
-
11B-604.8.1.4 Toe clearance
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters indicating elevator car controls shall not be...
-
3.5.2 Color of the ISA
Per section 703.7 of the ABAAS, the ISA shall be posted in high-contrast colors. The ISA is not required to be blue and white when posted on Federal lands.
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Plan 3A: 12-Foot Wide Accessible Guest Room
Plan 3A: 12-Foot Wide Accessible Guest Room This drawing shows an accessible 12-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Plan 1A: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Plan 1B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
§ 36.406(e) Housing at a place of education.
subject to this section shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
-
Visual Alarms, Notification Devices and Telephones [9.3] Auxiliary Alarms
Because guest room sizes are not large, it is required only that the signal, which is intended to alert persons who are awake, be visible in all areas of the room or unit....
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
§ 36.406(c) Places of lodging
proposed standards shall comply with the provisions of the proposed standards that apply to transient lodging, including, but not limited to the requirements for transient lodging guest rooms...
-
11B-809.1.3 Washing machines and clothes dryers
Where washing machines and clothes dryers are provided in residential dwelling units with mobility features, they shall comply with Section 11B-611. Washing machines and clothes...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...