Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
Search Results "Pull Side"
Commonly Searched Documents
-
§ 38.95(c)(4) Ramp barriers
-
§ 38.125(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.83(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
Problem Two (Entrance)
Solution: Short ramps or wedges may be used on both sides of the threshold to allow a voter in a wheelchair to pass over the threshold....
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
-
M21
If a coat hook is provided, is it mounted no higher than 54 inches above the floor for a side approach or 48 inches above the floor for a front approach?...
-
1133A.4.1, Item 3
The sides of adjacent cabinets and the back wall, which may become exposed to moisture or food handling when a countertop is lowered, shall be constructed of durable, nonabsorbent materials...
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL...
-
1133A.4.1, Item 3
The sides of adjacent cabinets and the back wall, which may become exposed to moisture or food handling when a countertop is lowered, shall be constructed of durable, nonabsorbent materials...
- Grohe Concetto Faucets
-
1. Standing Supports
preferred side to hold onto the standing support....
-
5. Edge Protection
of the platform, and for double ramped entry platforms, the Committee recommended a minimum two-inch high edge protection on both sides of the platform....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
407.4.1 Car Dimensions
Table 407.4.1 Elevator Car Dimensions Minimum Dimensions Door Location Door Clear Width Inside Car, Side to Side...
-
11B-604 Water closets and toilet compartments
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
-
Clear Floor Space [4.16.2]
Space at least 60 inches wide is necessary for side transfers and when provided a 56 inch depth is permitted for either a forward or side approach because of the maneuvering space available...
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. ...
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
The MDE NPRM proposed requiring standing supports on each side of the standing surface of diagnostic equipment used by patients in the standing position, and compliance with the technical...
-
Handrails
Handrails Handrails are required on both sides of ramps connecting elevated play components....
-
Clear Width [1016.3]
Consider the number of people who are likely to use the ORAR at the same time and how they will want to use it—single file or walking side-by-side....
-
J. Bedside Clearance
Regarding maneuvering space around the bed(s) in the accessible guestrooms... ...in accessible guestrooms with one bed, is there at least a 36" wide route on each side of the bed to allow...
-
4.1.3(19)(a)
space for each total seating capacity increase of 100 In addition, one percent, but not less than one, of all fixed seats shall be aisle seats with no armrests on the aisle side...