Section 608.2.3 covers the current ADA Standards for the size and clearances of alternate roll-in type shower compartments.
Search Results "Compartment Door"
Commonly Searched Documents
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.2.3
-
404.2.4.4 Floor or Ground Surface
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1.     Slopes not steeper...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
-
Wheelchair Accessible Gates
Web sites with designs that allow wheelchair access while restricting access by ATVs and motorcycles are listed near the end of this tech tip. The best Web site was that of Scottish...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4. If unattended security...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
6.14.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7.
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. Slopes not steeper than...
-
General Elements
Most scoping provisions apply to both interior and exterior elements where provided throughout facilities and sites (and are not limited to those in corridors as shown here).
- BEST Door Lever Hardware Cylindrical Locks - 9K
-
Plan 3A: 12-Foot Wide Accessible Guest Room
Features include a bathtub with a seat, comparable vanity, open clothes closet, and door connecting to adjacent guest room....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.3.2
Section 608.3.2 covers the current ADA Standards for grab bars in standard roll-in type shower compartments.
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
- Cavity Sliders USA Inc. Wall Mount Track
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
- Behavioral Safety Products #DH510 Mortise Ligature Resistant Integrated Door Lever
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Doors shall have a clear opening at least 32 inches wide when measured from the face of the door to the opposite stop when the door is opened 90 degrees and shall have hardware usable with...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
- Don-Jo Mfg., Inc. Door Flip Guards 1603
- Don-Jo Mfg., Inc. Door Flip Guards 1604