Clearance around a water closet shall comply with 604.3.
Search Results "Clear Width at Turn"
-
604.9.2 Clearance
-
Note
Note: In every instance, regardless of toilet and lavatory configuration, adequate space needs to be provided for inmates who use wheelchairs to transfer onto and off of the...
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
M8
M8. Is there at least 18 inches between the center of the toilet and the side of the adjacent lavatory? [ADA Standards § 4.16.2; Fig. 28] Yes No
-
Sinks [4.24]
Sinks [4.24] ADAAG provides technical specifications for both "lavatories" and "sinks." Requirements for lavatories in ADAAG 4.19 apply to fixtures for hand washing in toilet or...
-
4.23.2 Doors
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture.
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture.
-
11B-604.9.2 Clearance
11B-604.9.2 Clearance. Clearance around a water closet shall comply with Section 11B-604.3.
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
1009.2.2 Seat Location
1009.2.2 Seat Location. In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface...
-
604.9.2 Clearance
Clearance around a water closet shall comply with 604.3.
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
604.9.2 Clearance
604.9.2 Clearance. Clearance around a water closet shall comply with 604.3.
-
Accessible Sidewalks 2: Pedestrians with Ambulatory Impairments
Requires the Registered User plan or above. Login!
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Exterior Routes
width of walking surface. 11B-403.5.1 Contrasting stripe on upper approach and all treads. 11B-504.4.1 No open risers...
-
Exterior Routes
width of walking surface. 11B-403.5.1 Contrasting stripe on upper approach and all treads. 11B-504.4.1 No open risers...
-
806 Transient Lodging Guest Rooms
The Department’s drawings are sample plans, showing the layout of the space, relationship of elements to each other, and required clear floor and turning spaces....
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable....
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Areas of refuge are fire-resistance rated and smoke protected areas where those unable to use stairs can register a call for evacuation assistance and await instructions or...
-
Seats