3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
-
4.34.5.4(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
§ 38.107(a)(1)
floor, and may overlap a maximum of 19 inches, if the lowest portion of the fixture is a minimum of 29 inches above the floor, provided such fixtures do not interfere with access to the water...
-
4.34.5.5(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head at various heights or as a hand-held shower shall be provided....
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
7.3 Definitions
All trail-related definitions used in the FSTAG are from the Forest Service Manual or Handbook, the Forest Service Infra Trails Module, Trail Assessment and Condition Survey (TRACS)...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
36 CFR Part 1194 - Information and Communication Technology (ICT) Final Standards and Guidelines Jan. 2018 Amendments - Preamble
Corrections to the Information and Communication Technology (ICT) Final Standards and Guidelines Published in the Federal Register on January 22, 2018. 36 CFR Part...
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
- Moen Home Care Glacier 12" Grab Bar