Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
Search Results "Sloped Entry"
-
11B-1008.4.2 Clear floor or ground space
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
-
11B-206.2.7 Press boxes
Exceptions: An accessible route shall not be required to press boxes in bleachers that have points of entry at only one level provided that the aggregate area of all press boxes is...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
F206.7.5 Existing Site Constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
206.7.5 Existing Site Constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
502.4 Platform Accessibility Features
Section 9.3.3 Enable sequential entry of multiple (chorded) keystrokes; B. Section 9.3.4 Provide adjustment of delay before key acceptance; C....
-
502.4 Platform Accessibility Features
Section 9.3.3 Enable sequential entry of multiple (chorded) keystrokes. 2. Section 9.3.4 Provide adjustment of delay before key acceptance. 3....
-
11B-608.2.2 Standard roll-in type shower compartments
30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry...
-
Launch Ramps Without Boarding Piers
The portion of the accessible route located within the launch ramp is not required to comply with the slope requirements for accessible routes....
-
STREETS, ROADS AND WALKWAYS {35.150}
WALKWAYS {35.150} “If a public entity has responsibility or authority over streets, roads, or walkways, its transition plan shall include a schedule for providing curb ramps or other sloped...
-
504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
N. Mobility Disability or Mobility Disabilities
Disability" or "Mobility Disabilities" means any impairment or medical condition that limits a person’s ability to walk, ambulate, maneuver around objects, or to ascend or descend steps or slopes...
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
4.5.2 Changes in Level
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
4.5.2 CHANGES IN LEVEL
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in 2010 ADAS....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
Using the Polling Place Checklist
Using the Polling Place Checklist Tools and Documentation A few simple tools may be used to measure the sizes and the slope of specific elements and spaces: • A metal tape measure...
-
Transit Stops (R308.1) (Section-by-Section Analysis)
The slope of boarding platforms must not exceed 2 percent in any direction....
-
1010.1.7 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
- Corbin Russwin Inc. FE5400S Mult-Point Exit Device Latching System
- Spectrum Aquatics Glacier Platform Pool Lift
-
Gangways
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....