Knee and toe clearance complying with 306 shall be providing. (17” min. depth.) 902 Dining Surfaces and Work Surfaces. 902.3 Height....
Search Results "Maneuvering Clearance (Alcove)"
Commonly Searched Documents
-
Facility
-
L. Lavatory
Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl...
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. ◼...
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-T
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-T
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation
- Pilot Rock UT Series Side Accessible Picnic Table Using Recycled Plastic
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
-
Alterations
The seat of at least one spring rocker is between 11 inches (280 mm) and 24 inches (610 mm) maximum, and clear floor or ground space and maneuvering space is provided. ...
-
F206.2.4 Spaces and Elements
clerks' stations, bailiffs' stations, deputy clerks' stations, and court reporters' stations shall not be required to provide vertical access provided that the required clear floor space, maneuvering...
-
206.2.4 Spaces and Elements
clerks' stations, bailiffs' stations, deputy clerks' stations, and court reporters' stations shall not be required to provide vertical access provided that the required clear floor space, maneuvering...
-
Design Guidelines for the Hearing and Visually-Impaired
controls in accessible locations; reinforcements in bathroom walls to allow later installation of grab bars; and usable kitchens and bathrooms such that an individual in a wheelchair can maneuver...
-
Emergency Egress
other exit routes to avoid forcing a person using a wheelchair to travel against the general flow increased aisle widths along accessible egress routes to allow passing and easier maneuvering...
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A circular space is permitted to include knee and toe clearance. A T-shaped space is permitted to include knee and toe clearance only at the end of either the base or one arm....
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. Figure 505.4 Handrail Height...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. FIGURE 11B-505.4 HANDRAIL HEIGHT...