Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
Search Results "Input Floor"
Commonly Searched Documents
-
11B-603.3 Mirrors
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
Height: ADA Standard Section 611.4
Section 611.4 covers the current ADA Standards for the height of the laundry compartment in top loading machines and front loading machines.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
Multi-Story Buildings and Facilities: ADA Standard Section 206.2.3
Section 206.2.3 covers the scoping requirements in the most current ADA Standards for accessible routes within multi-story buildings and facilities
-
§382.57(c)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
§27.71(k)(5)(i) Speech output enabled.
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
§ 382.57(c)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
§ 27.71(k)(5)(i) Speech output enabled
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all other visual information for full use must be accessible to and independently...
-
Homemods.org
., sleeping on the first instead of second floor) and renovations (e.g., installing a roll-in shower)....
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
- Ampetronic HLS02 Intercom & Information Point Audio Induction Loop Driver Hearing System
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 360-degree turn. The bold dashed line in the table and figure indicates the...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
Knee clearance shall be provided at a depth of 11 inches minimum and 25 inches maximum at 9 inches above the floor and at a depth of 8 inches minimum at 27 inches above the floor....
-
11B-411.2.1.2.5 Audio output
Upon activation of the accessibility function button, the audio output shall provide verbal announcements, including but not limited to, operating instructions, user input confirmation,...
-
11B-411.2.1.2.5 Audio output
Upon activation of the accessibility function button, the audio output shall provide verbal announcements, including but not limited to, operating instructions, user input confirmation,...
-
Signal Type: ADA Standard Section 407.4.8.2.1
Section 407.4.8.2.1 covers the current ADA Standards for the signal type of audible elevator car indicators.
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...
- Collapsible Water Retainer Shower Dam for Shower Threshold Information Video
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.