that can be played simultaneously with the regular audio portion of the video material (adding description during pauses in the regular audio), or it can be added to (or "mixed" with) an existing...
Search Results "Existing Theaters"
-
Video Description (Advisory Guidance)
-
4. Access to Newly Constructed and Altered Facilities
In addition, the City will upgrade noncompliant curb ramps and/or install new curb ramps where existing ramps are lacking in connection with street resurfacing and repaving and other major...
-
Alterations. (Section-by-Section Analysis)
Although the 2010 Standards contain specifications for alterations in existing detention and correctional facilities, section 232.2 defers to the Attorney General the decision as to the...
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
11B-407.2.1.2 Size and shape
[2010 ADAS] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
§ 37.135(c)(1)
ETA Editor's Note The above referenced section 37.138 does not currently exist, according to ecfr.gov....
-
11B-407.4.6.1 Location
In existing elevators, car control buttons with floor designations shall be permitted to be located 54 inches (1372 mm) maximum above the finish floor where a parallel approach is provided...
-
907.5.2.3.3 Group R-2
interconnection of the building fire alarm system with the unit smoke alarms, replacement of audible appliances with combination audible/visible appliances, or future extension of the existing...
-
11B-407.2.1.2 Size and shape
[2010 ADA Standards] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would...
-
407.2.2.2 Visible Signals
Existing elevators shall not be required to comply with 407.2.2.2....
-
407.4.6.1 Location
In existing elevators, car control buttons with floor designations shall be permitted to be located 54 inches (1370 mm) maximum above the finish floor where a parallel approach is provided...
-
407.2.2.1 Visible and Audible Signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-604.4 Seats
A 3-inch (76 mm) high seat shall be permitted only in alterations where the existing fixture is less than 15 inches (381 mm) high....
-
11B-604.4 Seats
A 3-inch (76 mm) high seat shall be permitted only in alterations where the existing fixture is less than 15 inches (381 mm) high....
-
A11yNYC - Accessibility New York City
Our group exists to advance digital accessibility and inclusive design. Our goal is to bring together NYC's accessibility community to share ideas, best practices, and our experiences....
- Federal Elevator Carelift Wheelchair Lift
- SafetyStepTD Ramp-Up Detectable Warning System
- SafePath BigHorn™ Ramps
- SafePath VulcanLanding™ Rubber Transition Ramp
- AssistiveWare News-2-You
-
Section 36.201(b) (Preamble, Section-by-Section Analysis)
The ADA was not intended to change existing landlord/tenant responsibilities as set forth in the lease....
-
Section 36.201(b) (Section-By-Section Analysis and Response to Comments)
The ADA was not intended to change existing landlord/tenant responsibilities as set forth in the lease....