Henderson Elementary School, 1800 Dismuke Street, Houston, TX Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the...
Search Results "Ramp Surface"
-
Polling place violations that can be remediated with temporary measures
-
DSA Drawing 11B-406-5C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
Clear Deck Space: ADA Standard Section 1009.2.3
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
1013.4 Height
This section requires tent platforms to be 19 inches high maximum measured from the clear ground space to the tent platform surface....
-
§ 38.159(b)(6) Platform surface
(6) Platform surface. The platform surface shall be free of any protrusions of 1/4 inch (6.5 mm) high and shall be slip resistant....
-
2. Age of Streets and Sidewalks
In addition, the requirements vary depending on the age of a highway, road, street, or sidewalk, and depending on when and whether it was paved, repaved, resurfaced beyond normal...
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
R304.5.5 Clear Space
R304.5.5 Clear Space. Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street...
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).