Search Results "Grab Bar Height"
Commonly Searched Documents
- Kompan, Inc. Flexus GXY919
-
Design Criteria for the Transfer Station
The station was designed to investigate the impact handhelds, back rests, heights, and seat widths have on transfer performance....
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
ETA Summary of ADAAG/CBC Signage Requirements
ADAAG/CBC Signage Requirements Click here to view/download the pdf version (1.22 MB)
-
ETA Summary of ADA Signage Requirements
Summary of ADA Signage Requirements Click here to view/download the pdf version (162 KB).
-
6.2 Presentations that Informed the Minimum Height Deliberations
about the minimum transfer surface height recommendation....
-
Types of Alternative Designs
The positioning and type of grab bars were also changed to provide more room and flexibility....
- Roadtech Manufacturing Retractable Cone Bar Barricades and Barriers
- Zurn Z5560 Commercial EcoVantage Elongated Toilet ADA Height
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
-
Size and Clearances [4.21.2]
The 36 by 36 inch dimension, measured to the interior finish, keeps front and side grab bars within reach from the seat....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in 308. [ECTCR UFAS 4.34.6.10(2)]
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.