., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than 15 inches, above the floor...
Search Results "Floor Slope"
-
§ 38.127(c)
-
1.2 Q. Does the Fair Housing Act cover four one-story dwelling units that share common walls and have individual entrances?
The Fair Housing Act applies to all units in buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings...
-
11B-233.3.1.2.6.2 Test number one, individual building test
The slopes of the undisturbed site measured in a straight line between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15,240 mm) of the planned entrance...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element. Exceptions: 1. ...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Slope. Each designated accessible parking space shall be flat and level with slopes and cross-slopes not exceeding 1:50 (2%) in all directions. Standards § 4.6.3. e. ...
-
2.1 Q. If a building includes three residential dwelling units and one or more commercial spaces, is the building a covered multifamily dwelling under the Fair Housing Act?
Covered multifamily dwellings are buildings consisting of four or more dwelling units, if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
Key Differences Between Routes
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Accessible Means of Entry to Pools
This section requires that at least one entry will have to be a sloped entry or a pool lift; the other could be a sloped entry, pool lift, a transfer wall, or a transfer system (technical...
-
Water Closet Clearance
To allow greater transfer options, including side transfers, the 2010 Standards prohibit lavatories from overlapping the clear floor space at water closets, except in covered residential...
-
Sec. 469.103. Modification of Approved Plans and Specifications.
Approved plans and specifications to which any substantial modification is made shall be resubmitted to the department for review and approval.
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may...
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and...
-
Space Allowance and Reach Ranges [4.2]
Adult dimensions and measures for standard manual wheelchairs form the basis of many ADAAG specifications. For example, the specified height of toilets and shower seats (17-19...
-
Dimensional Tolerances in Construction and for Surface Accessibility
[See subsections ...]
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....