• Recessed alternate roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor...
Search Results "Floor Destination Indicator"
-
Plan 2B: 13-Foot Wide Accessible Guest Room
-
Features of an Accessible Examination Room
A clear floor space, 30” X 48” minimum, adjacent to the exam table and adjoining accessible route make it possible to do a side transfer. 2....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...
-
7(2)(a)(ii)
(ii) Clear floor space is provided at fixtures as shown in Fig. 7 (a), (b), (c) and (d). Clear floor space at fixtures may overlap....
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any...
-
Sec. 469.102. Procedure for Submitting Plans and Specifications
[See subsections ...]
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
- Figure 810.3 Bus Shelters – Drawing from the U.S. Access Board
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor....
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor space...
- ADA and the FTA: Improving Transit Access for People with Disabilities
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
11B-809.10.4 Sufficient maneuvering space
Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing....
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]
-
Evaluate and adjust the volume of the Walk indication
Evaluate and adjust the volume of the Walk indication Stand at the curb or end of the curb ramp at the crosswalk and listen for the Walk indication....
-
Appendix 2- Photos of Participants in the IDEA Center Research
Appendix 2- Photos of Participants in the IDEA Center Research Examples of High Seats: Examples of Very Large and Small Clear Floor Area Widths: Examples of Very Long...
- Access Board: Toilet Rooms
-
10.1 Q. Is it necessary to have an accessible path of travel from a subterranean garage to single-story covered multifamily dwellings built on top of the garage?