11B-405.9.2 Curb or barrier
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
- Triton Centerset Commercial Bathroom Sink Faucet
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....
-
Location: ADA Standard Section 409.3.2
Section 409.3.2 covers the current ADA Standards for the location of private residence elevator doors.
-
Residential Dwelling Unit Communication Systems: ADA Standard Section 708.4
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-809.8 Doors
The floor or landing at primary entry doors, required exit doors, and secondary exit doors where a change in elevation occurs between the interior and the exterior surface of the floor or...
-
Mobility
And transitions from surface texture – going from carpet to tile – can be a tripping hazard. To people who can’t see that texture change, that could increase the risk....
-
Height: ADA Standard Section 407.4.6.4.1
Section 407.4.6.4.1 covers the current ADA Standards for the height of the emergency controls in elevator cars.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
- Olympia i2 Single Handle Diverter Set P-2280
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....