Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
Search Results "Space Allowance"
-
11B-802.2.1.2 Lines of sight between heads
-
802.2.2.1 Lines of Sight over Heads
Where standing spectators are provided lines of sight over the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded...
-
802.2.1.1 Lines of Sight over Heads
Where spectators are provided lines of sight over the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines...
-
Lines of Sight and Dispersion: ADA Standard Section 221.2.3
Section 221.2.3 covers scoping requirements in the current ADA Standards for lines of sight and dispersion of wheelchair spaces in assembly areas.
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
11B-802.2.2.2 Lines of sight between heads
standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces...
-
802.2.1.2 Lines of Sight between Heads
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
802.2.2.1 Lines of Sight over Heads
Where standing spectators are provided lines of sight over the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded...
-
802.2.2.2 Lines of Sight between Heads
standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces...
-
802.2.1.2 Lines of Sight between Heads
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
2.6.1 Size
The passing space shall be either:Â ...
-
Ticket sales. (Section-by-Section Analysis)
A ‘‘wheelchair space'' refers to a space for a single wheelchair and its occupant....
-
F227.2 Check-Out Aisles
[ECTCR UFAS 7.3] EXCEPTION: Where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with 904.3 shall be required....
-
227.2 Check-Out Aisles
EXCEPTION: Where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with 904.3 shall be required....
-
227.2 Check-Out Aisles
EXCEPTION: Where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with 904.3 shall be required....
-
802.2.2.2 Lines of Sight between Heads
standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces...
-
11B-707.2 Clear floor or ground space
11B-707.2 Clear floor or ground space. A clear floor or ground space complying with Section 11B-305 shall be provided....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
- Bobrick Accessibility Video -- Design for Turning Radiuses
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
Forward Approach
For wheelchair access, the proposed rule required a forward approach at cantilevered units but allowed a parallel approach at other types of units, such as those that are floor mounted....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....