Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
Search Results "Patient Change Area"
-
305.2 Floor or Ground Surfaces
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3. EXCEPTION: Diagnostic equipment with entry and exit permitting pass-through...
-
Physical Access
Resources found at http://www.hfcdihp.org/products.html Choosing and Negotiating an Accessible Facility Location Improving Accessibility with Limited...
-
M304.3 Standing Supports
Standing supports shall be provided on each side of the standing surface and shall comply with M305.3.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
Element-by-element safe harbor for public accommodations. (Section-by-Section Analysis)
These incremental changes were made to address technological changes that have occurred since the promulgation of the 1991 Standards, to reflect additional study by the Access Board, and...
-
11B-207.1 General
Areas of refuge shall not be required in detention and correctional facilities. Accessible means of egress are not required to be provided in existing buildings....
-
Side reach (Section-by-Section Analysis)
If the pay phones comply with the 1991 Standards, the adoption of the 2010 Standards does not require retrofitting of these elements to reflect incremental changes in the 2010 Standards....
-
Side reach (Section-by-Section Analysis)
If the pay phones comply with the 1991 Standards or UFAS, the adoption of the 2010 Standards does not require retrofitting of these elements to reflect incremental changes in the 2010 Standards...
-
Serving Counters
When it is not readily achievable to provide an accessible counter or bar area or service at accessible tables in the same area, then a business should provide service in an alternative...
-
F. Chapter 5: Doorways, Circulation Paths, and Fare Collection Devices
Chapter 5 in the 2016 Non-Rail Vehicle Guidelines contains the technical requirements for doorways, illumination at doorways and boarding and alighting areas, passenger access routes, and...
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....