The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-411.2.2.1 Visible identification
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and the opposing...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with...
-
4.1.7(3) Historic Preservation
(3) Historic Preservation: Minimum Requirements:...
- Election Systems & Software ADA Sip-N-Puff - AutoMark
-
Rear Grab Bar
The proposed rule specified that the rear grab bar be 24 inches long minimum, centered on the water closet, or at least 36 inches long "where wall space permits" (604.5.2)....
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
Breast Platform [M303.4.1]
Rationale: The subcommittee expressed conflicting perspectives on the minimum breast platform height with members either choosing to support the 26-inch or 28-inch minimum....
-
Sec.36.602 General rule
On the application of a State or local government, the Assistant Attorney General may certify that a code meets or exceeds the minimum requirements of the Act for the accessibility and usability...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
604.8.2.2 Doors
with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. ...
-
604.8.2.2 Doors
with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum...
-
R305.1.1 Dome Size
The truncated domes shall have a base diameter of 23 mm (0.9 in) minimum and 36 mm (1.4 in) maximum, a top diameter of 50 percent of the base diameter minimum and 65 percent of the base...
-
4.6.5* Vertical Clearance
Provide minimum vertical clearance of 114 in (2895 mm) at accessible passenger loading zones and along at least one vehicle access route to such areas from site entrance(s) and exit(s)....
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
The Target Population
For many dimensions women represent the smaller end of the distribution....
-
Q2.) What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
Those are usually the dimensions that can safely be considered industry tolerances. ...
-
3.3.5 Seat Height
3.3.5 Seat Height Height dimension standards for seats prescribed in the Australian, Canadian and U.S. standards were very similar (480 mm or 18.9 in., 480 mm or 18.9 in. and 485 mm...
-
Suggested accessibility guidelines for exterior concrete surfaces
However, the ACI standards do not permit interpolation or extrapolation for dimension greater than or less than 10 feet....
-
Areas for further work
Measurement instruments Accuracy of instruments/measurement uncertainty Use of significant figures Metric conversions or dual unit standards Measurement of dimensions...