The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
602.6 Water Flow
-
604.7 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
Test Courses & Surfaces
., compacted to a depth of 5 in.) CPBR Engineered Wood Fiber J (loose-fill processed wood fibers, compacted to a depth of 5 in.)...
-
Wheelchair Spaces (M303.2)
M303.2 includes technical criteria for orientation, width, depth, and knee and toe clearance at wheelchair spaces....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor....
-
Bathroom Do’s and Dont’s
Include bathroom towel bars/hooks within reach of the shower or bench, so an individual does not have to travel across the bathroom using a mobility aid device....
-
1136A.1 Receptacle heights
If the reach is over a physical barrier or an obstruction (for example, a kitchen base cabinet), receptacles shall be located within the reach ranges specified in Section 1138A.3....
- Delta Single Handle Pull-Out Kitchen Faucet 472-DST
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. ...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
1. Whether this person currently is able to perform this specific job, with or without an accommodation
For example: The evaluation may indicate that a person can lift up to 30 pounds and can reach only 2 feet above the shoulder; the job as usually performed (without accommodation) requires...
-
End Note
For specific information about how to comply with the ADA and reach this nearly untapped audience of people with disabilities, visit the U.S....
-
Shower
The lowered walls would enable caregivers to reach and use a hand held shower from outside the shower to assist a care recipient....
-
NOTICE OF CLASS ACTION
The class action settlement ("Settlement Agreement"), which must be approved by the United States District Court, was reached in the case entitled Willits v....
-
§ 38.95(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section; sufficient clearances to permit a wheelchair or mobility aid user to reach a seating location;...
- Stanley Hardware 8179 Light Commercial Door Closer
-
Privacy: ADA Standard Section 707.4
In addition to people who are blind or visually impaired, people with limited reach who use wheelchairs or have short stature, who cannot effectively block the ATM screen with their bodies...
-
11B-217.2 Wheelchair accessible telephones
1 bank At least 50 percent of telephone units per bank, but not less than 1 per bank At least 1 telephone per floor shall meet the requirements for a forward reach...
-
11B-220.1 Automatic teller machines and fare machines
Accessible ATMs, including those with speech and those that are within reach of people who use wheelchairs, must provide all the functions provided to customers at that location at all times...