R411 International Symbol of Accessibility (Section-by-Section Analysis) The technical requirements ramps, stairways, handrails, visual characters on signs, and the International Symbol...
Search Results "Handrail Clearance"
Commonly Searched Documents
- 
    
  
  R411 International Symbol of Accessibility (Section-by-Section Analysis)
  
 - 
    
  
  Library
  
Offset pivot hinge on door to library Large print books in the library Handrails at two height Evaporative cooler to save the energy used by air conditioners...
 - 
    
  
  1. Abdomen depth (AD)
  
Univariate analysis The univariate analysis examines AD alone and is appropriate when no other clearance dimension is constrained or bounded (e.g., knee clearance height, foot clearance...
 - 
    
  
  Associated
  
Associated TAS 604.3.2 allows “associated” grab bars, dispensers, sanitary napkin disposal units, coat hooks, and shelves to overlap the required clearance around an accessible water...
 - 
    
  
  General: ADA Standard Section 410.1
  
Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.
 - 
    
  
  11B-608.2.1 Transfer type shower compartments
  
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
 - 
    
  
  Clear Deck Space: ADA Standard Section 1009.4.1
  
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
 - 
    
  
  11B-1009.4.1 Clear deck space
  
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
 - 
    
  
  11B-302.3 Openings
  
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
 - 
    
  
  1003 Recreational Boating Facilities
  
Requirements for accessible routes and ramps are applied to gangways, but exceptions to criteria for maximum rise and slope, handrail extensions, and level landings are provided....
 - 
    
  
  Do drinking fountains pose hazards as protruding objects?
  
This is not required for wheelchair accessible units with no more than a 27” clearance below (the minimum required for knee clearance and the maximum recognized for cane detection)....
 - 
    
  
  Introduction
  
Introduction This memo provides a revised description and analyses examining knee clearance dimensions in mammography equipment (as requested in your email dated: 4/15/2013)....
 - 
    
  
  Steps
  
Most building codes require handrails for a certain change in level or number of steps....
 - 
    
  
  Transfer Type Shower Compartments: ADA Standard Section 608.2.1
  
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
 - 
    
  
  Doors: ADA Standard Section 604.8.2.2
  
Section 604.8.2.2 covers the current ADA Standards for ambulatory accessible compartment doors.
 - 
    
  
  604.3.1 Size
  
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
 - 
    
  
  A4.6.3 PARKING SPACES
  
High-top vans, which disabled people or transportation services often use, require higher clearances in parking garages than automobiles....
 - 
    
  
  1133B.2.4.2
  
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
 - AquaTrek2 ADA Wading Pool Ramp
 - 
    
  
  Clear Width [4.8.3]
  
The minimum dear width for ramps of 36 inches is measured between the leading edge of handrails. A maximum clear width is not specified....
 - 
    
  
  Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
  
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features....
 - 
    
  
  Question: Alteration vs. Maintenance for Stairs in Pre-ADA Building
  
However, some of the existing wooden handrails are rotted and need to be replaced....
 - Kompan, Inc. Elements Play Structures Tower ELE400050