When the top of the breast platform is at the height of the patient’s breasts, there must be sufficient clearance at the height of the patient’s knees, as is shown in Figure 5.8.2.1....
Search Results "Grab Bar Height"
Commonly Searched Documents
-
5.8.2.1 Height of Breast Platform at Time of Measurement
-
H. Drop-off Area Height
Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area?...
-
4.34.5.2(3)
(3) Structural reinforcement or other provisions that will allow installation of grab bars shall be provided in the locations shown in Fig. 47(b)....
-
11B-903.4 Back support
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
-
M305.2.5 Surface Hazards
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
5.4 Transfer Supports
5.4 Transfer Supports.
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations
-
Fishing Facilities
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.8MB) PDF Non-Fillable Form (0.7MB)
-
II. DISCUSSION
The Court requested that the United States address the following questions: Under the above-described circumstances, does ADAAG 904.4.1’s exception apply such that the sales...
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
ADAPTABLE
As part of the initial design and construction, for example, structural backing would be provided for the later installation of grab bars, base cabinets under kitchen sinks would be removable...
-
1009.7.2 Riser height and tread depth
1009.7.2 Riser height and tread depth. ... Exceptions: 6. See Section 3404.1 for the replacement of existing stairways. ...
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
Typical Transfer Techniques: Staff Assistance and Patient Lifts
Typical Transfer Techniques: Staff Assistance and Patient Lifts Some individuals will need additional assistance to get on and off an exam table, even if it lowers to 17‒19 inches...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...