An entrance that is made available for common use on a controlled basis, but not public use, and that is not a service entrance....
Search Results "Flush Control"
-
RESTRICTED ENTRANCE
-
RESTRICTED ENTRANCE
An entrance that is made available for common use on a controlled basis, but not public use, and that is not a service entrance....
-
Swimming Pools, Wading Pools & Spas
Word Fillable Form (2.8MB) Word Non-Fillable Form (2.6MB) PDF Non-Fillable Form (1.0MB)
- EZJamb SlideSet Modern Pocket Door Frame System
-
11B-407.4.6.3 Keypads
Car control keypads shall be in a standard telephone keypad arrangement and shall comply with Section 11B-407.4.7.2....
-
11B-407.4.6.3 Keypads
Car control keypads shall be in a standard telephone keypad arrangement and shall comply with Section 11B-407.4.7.2....
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department....
-
11B-809.10.6.3 Clearance
A clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided outside the shower as illustrated in Figure 11B-809.10.6.3...
-
Faucets: ADA Standard Section 606.4
Section 606.4 covers the current ADA Standards for the faucet controls of lavatories and sinks.
-
Grab Bars [4.16.4]
In existing facilities where the location of the flush valve conflicts with the grab bar, the bar can be split or shifted to the wide side....
-
Passenger Loading Zones [4.6.6]
Where aisles are flush with the pull-up space, wheelchair transfer is easier (the change in level of aisles at curb height can make transfer very difficult)....
-
Edge Protection
Recommendation: At narrow routes in particular, consider maintenance of adjacent surfaces as raised or flush or wider route widths in consideration of minimum maneuvering and passage requirements...
-
Wheelchair Spaces
Wheelchair spaces must be level (2% maximum slope in any direction) and adjoining routes and maneuvering spaces must provide flush connections so that maneuvering to and from spaces does...
- SDC Electrified Lockset HiTower® Pro 7500 Series
-
R208.1 Where Required
On pedestrian access routes, detectable warning surfaces indicate the boundary between pedestrian and vehicular routes where there is a flush rather than a curbed connection....
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
Illumination: ADA Standard Section 407.4.5
Section 407.4.5 covers the current ADA Standards for the illumination of the elevator car controls, platform, car threshold and car landing sill.
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
907.4.2.2 Height
CBC Section 11B-309.4 requires controls and operating mechanisms to be operable with one hand without tight grasping, pinching or twisting of the wrist (must be operable by persons with...