(For example, repairing cracks in sidewalks on exterior routes; placing portable display racks and potted plants so they do not impede exterior and interior routes; snow removal on exterior...
Search Results "Exterior Ramp"
-
5. Accessible Features
-
Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
-
Counter Slope: ADA Standard Section 406.2
Section 406.2 covers the current ADA Standards for counter slope of adjoining gutters and road surfaces immediately adjacent to curb ramps.
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
11B-302.1 General
Additional information regarding accessible exterior surfaces is available on the US Access Board website at http://www.access-board.gov/research/completed-research/accessible-exterior-surfaces...
-
11B-302.1 General
Additional information regarding accessible exterior surfaces is available on the US Access Board website at http://www.access-board.gov/research/completed-research/accessible-exterior-surfaces...
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
-
4.3.11.1(2)
(2) A portion of an exterior exit balcony located immediately adjacent to an exit stairway when the balcony complies with local requirements for exterior exit balconies....
-
704.7 Unexposed surface temperature
Where protected openings are not limited by Section 704.8, the limitation on the rise of temperature on the unexposed surface of exterior walls the exterior wall in any story, the total...
-
704.9 Vertical separation of openings
Openings in exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm...
-
TABLE OF CONTENTS
ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND TECHNICAL REQUIREMENTS 4.1 Minimum Requirements 4.1.1* Application 4.1.2 Accessible Sites and Exterior Facilities: New Construction...
-
PUBLIC USE
[DSA-AC] Interior or exterior rooms, spaces or elements that are made available to the public. Public use may be provided at a building or facility that is privately or publicly owned....
-
Eunice Noell-Waggoner, IES, LC. Value, Contrast and Reflections
These edited Proceedings are based on notes by JEW and TOS, and slides that accompanied the presentation) Exterior Considerations (slides 2 and 3) Contrast is needed at ramps &...
-
4.13.11(2)(a)
(a) exterior hinged doors: (Reserved)....
- CalCasp Training: 2016 California Building Code Chapter 11A
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
COMMON USE
Interior or exterior circulation paths, rooms, spaces or elements that are not for public use and are made available for the shared use of two or more people....
-
COMMON USE
Interior or exterior circulation paths, rooms, spaces or elements that are not for public use and are made available for the shared use of two or more people....
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADA Standards] 210.1 General....
-
11B-404.2.4.1 Swinging doors and gates
Add 6 inches (152 mm) at exterior side of exterior doors....
-
11B-404.2.4.1 Swinging doors and gates
Add 6 inches (152 mm) at exterior side of exterior doors....
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADA Standards] 210.1 General....
-
1010.1.7 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
- ADA Checklist for Existing Facilities