Performance Areas An accessible route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to dressing rooms...
Search Results "Unisex Toilet Room"
Commonly Searched Documents
-
Performance Areas
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
15(e)
(e) Within the timeframe set forth in subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of rooms for guests with...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
9.2.2(2)
(2) An accessible route complying with 4.3 shall connect all accessible spaces and elements, including telephones, within the unit, sleeping room, or suite....
-
404.2.4 Maneuvering Clearances
[ECTCR UFAS 4.13.6, Fig. 25] EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
Classes of Sleeping Accommodations [9.1.4]
in the number of accessible rooms that must be provided....
-
11B-809.10.5.3 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4. Exception: Shower spray units are not required in bathtubs.
- Access Board: Vertical Clearance for Protruding Objects
- Access Board: Tactile Sign Scoping
-
Emergency Planning
Emergency planning must be done well in advance for all events, and it is important to know that facilities and their staff members are prepared. During your inspection, be sure...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Doorways leading to toilet rooms and bathing rooms shall be identified by a geometric symbol complying with Section 11B-703.7.2.6....
- Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment – Drawing from the U.S. Access Board