Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
Search Results "DAISY: Digital Accessible Information System"
Commonly Searched Documents
-
Location and Spacing
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
4.28 Alarms
[See subsections ...]
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound...
-
2.1.2.3 New York State Standards
2.1.2.3 New York State Standards Ambient electro-magnetic fields should not exceed 30 mA/meter; higher levels would preclude the installation of an IL in the particular location....
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum...
-
4.28 ALARMS
[See subsections ...]
-
A4.28.2 AUDIBLE ALARMS
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
A4.28 ALARMS
[See subsections ...]
-
11B-706.6 Peak clipping level
11B-706.6 Peak clipping level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
§ 37.193 Interim service requirements
 [56 FR 45621, Sept. 6, 1991, as amended at 76 FR 57936, Sept. 19, 2011]
-
11B-708.3 Handsets
11B-708.3 Handsets. Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
12. Personal Care Attendant (PCA)
While PCAs may travel with a passenger with a disability, transportation agencies are not required to provide a personal care attendant or personal care attendant services to meet...
-
§ 37.35 Supplemental service for other transportation modes
[See subsections ...]
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
Components: ADA Standard Section 402.2
Section 402.2 covers the current ADA Standards for components of an accessible routes.
-
703.7.2.1 International Symbol of Accessibility
(F216.5) ï‚· If the main entrance to a building is not accessible, the ISA and an arrow to be posted to direct to closest accessible entrance....
-
§35.133 Maintenance of accessible features (Section-by-Section Analysis)
and equipment that are required to be readily accessible to and usable by persons with disabilities by the Act or this part....
-
Stages.
In addition, the Department would like specific information on whether, because of local law or policy, auditorium operators are already providing a direct accessible route to their stages...
-
Making Community Emergency Preparedness and Response Programs Accessible to People with Disabilities
Making local government emergency preparedness and response programs accessible to people with disabilities is a critical part of this responsibility....
-
Issue: 9-1-1 Systems
Common Problem: City governments do not provide direct and equal access to 9‒1‒1 systems, or similar emergency response systems, for individuals who are deaf or hard of hearing and use...