The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the...
Search Results "Building Permit"
Commonly Searched Documents
-
604.5.2 Rear Wall
-
Architectural Barriers Act
Architectural Barriers Act The Architectural Barriers Act (ABA) requires that buildings and facilities that are designed, constructed, or altered with Federal funds, or leased by a Federal...
-
704.10 Vertical exposure
For buildings on the same lot, approved protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent...
-
Applying the Forest Service Outdoor Recreation Accessibility Guidelines
When we build something, we need to build it for everybody (figure 33). FSORAG, however, doesn't require the installation of any particular feature....
-
703.7.2.1 International Symbol of Accessibility
(F216.5) If the main entrance to a building is not accessible, the ISA and an arrow to be posted to direct to closest accessible entrance....
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way. [2010 ADAS] Accessible Means of Egress....
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6.
addition to the provisions of Section 1.1.8.1 of this part, the provisions of this section shall apply to a city, county, and cities and counties adopting local energy standards applicable to buildings...
-
ACCESSIBLE ROUTE
[DSA-AC & HCD 1-AC] A continuous unobstructed path connecting accessible elements and spaces of an accessible site, building or facility that can be negotiated by a person with a disability...
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
1.2.3 Alternative materials, design and methods of construction and equipment
An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the...
-
M302.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
M305.2.2.2 Side Transfer Supports
Where transfer surfaces are part of an articulating surface, the support shall be permitted to be 15 inches (380 mm) long minimum. 2....
-
M301.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
5.8.2.7 Base Support Allowance
Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½ inches high....
-
Exceptions [1014.1, Exceptions 1 and 2]
When a condition for exception does not permit full compliance with a specific provision in the technical requirements for camp shelters, the camp shelter must comply with the specific provision...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
§ 36.406(d)(2)
Transfer type showers are not permitted in lieu of a roll in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted....
-
§ 35.151(e)(2)
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted....
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
Accessibility Standards in Title II Regulations Issued by DOJ
, they provide that new construction and alterations that commence on or after March 15, 2012, must comply with the 2010 Title II ADA Standards.[25] The revised Title II regulations permit...
-
502.3 Access Aisle
Two parking spaces shall be permitted to share a common access aisle. Parking access aisles must be part of an accessible route to the building or facility entrance....