The 1600A Series ADA Compliant Emergency Phones are designed to provide quick and reliable handsfree communication for any standard analog telephone line or analog phone system station port...
Search Results "Private Rail System"
Commonly Searched Documents
- Viking E-1600-45A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
-
2.1.4 Issues
* Only about 30 percent of modern hearing aids in the United States include a telecoil (more than twice this number use telecoils in Europe, which may help explain the popularity of IL systems...
-
§27.71(k)(5)(ii) Volume control.
(ii) Volume control. Automated kiosks must provide volume control complying with paragraphs (k)(5)(ii)(A) and (B) of this section.
-
§ 27.71(k)(5)(ii) Volume Control
(ii) Volume control. Automated kiosks must provide volume control complying with paragraphs (k)(5)(ii)(A) and (B) of this section.
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
- Paratransit Emergency Preparedness and Operations Handbook
-
[F] 907.5.2.3.4 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
215 Fire Alarm Systems
Alarm systems required to be accessible by 4.1 shall comply with 4.28. 215.2 Public and Common Use Areas....
-
[F] 907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
217.4.7 Transportation Facilities
In transportation facilities, in addition to the requirements of 217.4.1 through 217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail facility,...
-
F217.4.7 Transportation Facilities
In transportation facilities, in addition to the requirements of F217.4.1 through F217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail facility...
-
217.4.7 Transportation Facilities
In transportation facilities, in addition to the requirements of 217.4.1 through 217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail facility,...
- Accessible AlertSanDiego
-
11B-217.4.7 Transportation facilities
transportation facilities, in addition to the requirements of Sections 11B-217.4.1 through 11B-217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail...
-
11B-217.4.7 Transportation facilities
transportation facilities, in addition to the requirements of Sections 11B-217.4.1 through 11B-217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail...
-
E. M305 Supports
M305 provides the technical requirements for supports on medical diagnostic equipment. There were multiple significant changes made to the transfer supports section, including the...
-
10.1 General
Every station, bus stop, bus stop pad, terminal, building or other transportation facility, shall comply with the applicable provisions of 4.1 through 4.35, sections 5 through 9, and...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
-
§ 38.83(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
§ 38.93(d)(4) Exception
(4) Exception. Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of...
-
§ 38.95(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches,...
-
2.1.2 Standards
2.1.2 Standards There are no national US standards that define the required performance of IL systems....
-
Visible Alarms
Section 215.3 of the 2010 Standards provides that where employee work areas in newly constructed facilities have audible alarm coverage they are required to have wiring systems that are...
-
4. Obstructions
Fixed route operators would not have to establish flag stop or route-deviation policies, as these would be fundamental alterations to a fixed route system rather than reasonable modifications...