- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
- Figure 407.4.1(b) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(e) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(d) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Access Board: Clear Floor or Ground Space
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303. Exceptions: 1. ...
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303. Exceptions: 1. ...
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor...
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
a) Curb Ramps
For example, 5 points are deducted for lips greater than a half-inch; 12 points for a running slope between 8.33 percent and 10 percent; 25 points for a running slope greater than 10 percent...
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH