have over 300 linear feet of swimming pool wall and are not being altered will be required to provide only one (rather than two) accessible means of entry, at least one of which must be a sloped...
-
1007.3.2 Golf Club Reach Range Area
where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum having a running slope...
-
11B-1007.3.2 Golf club reach range area
where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum having a running slope...
-
1007.3.2 Golf Club Reach Range Area
where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum having a running slope...
-
4.6.3* PARKING SPACES
Parking spaces and access aisles shall be level with surface slopes not exceeding 1:50 in all directions....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
1007.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1010....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1. ...
-
11B-240.2.1.2 Additional number and types
Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
F240.2.1.2 Additional Number and Types
EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
240.2.1.2 Additional Number and Types
EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
240.2.1.2 Additional Number and Types
EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
11B-240.2.1.2 Additional number and types
Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
11B-240.2.1.2 Additional number and types
Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
T503.1 General
Illumination shall be provided at ramps, bridgeplates, doorways, and boarding and alighting areas in accordance with T503....
-
Curb Ramps
[See subsections ...]