(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off.
Search Results "Vehicle Pull-Up Space"
-
§ 38.83(c)(4) Ramp barriers
-
§ 38.159(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds (2665 N). Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4. Where EVCS...
-
11B-502.7.1 Arrangement
Parking spaces and access aisles shall be designed so that persons using them are not required to travel behind parking spaces other than to pass behind the parking space in which they parked...
-
11B-502.7.1 Arrangement
Parking spaces and access aisles shall be designed so that persons using them are not required to travel behind parking spaces other than to pass behind the parking space in which they parked...
-
11B-502.7.1 Arrangement
Parking spaces and access aisles shall be designed so that persons using them are not required to travel behind parking spaces other than to pass behind the parking space in which they parked...
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
§ 38.83(b)(8) Platform entrance ramp
not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform or roadway to ramp may be vertical without edge treatment up...
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum. FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE...
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
1011.2 Clear Ground Space
This section requires a clear ground space to be provided at outdoor constructed features and includes specific provisions for the size and location (1011.2.1), surface (1011.2.2), slope...
-
11B-221.2.1.3 Other boxes
Wheelchair spaces shall be located in not less than 20 percent of all boxes provided. Wheelchair spaces shall comply with Section 11B-802.1. Advisory 11B-221.2.1.3 Other boxes....
-
11B-221.2.1.3 Other boxes
Wheelchair spaces shall be located in not less than 20 percent of all boxes provided. Wheelchair spaces shall comply with Section 11B-802.1. Advisory 11B-221.2.1.3 Other boxes....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-806.2.3.1 Personal lift device floor space
In transient lodging facilities, clearance for the use of a personal lift device shall be provided under the bed(s) and adjacent to the clear floor space required by Section 11B-806.2.3....
- Diversified Woodcrafts ADA Compatible Mobile Lab Station with Flat Top 4352KF-RS
-
§ 38.159(b)(8) Platform entrance ramp
not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75 mm), and the transition from roadway or sidewalk to ramp may be vertical without edge treatment up...
-
F244.2.3.2 Parking Spaces
Where provided, parking spaces shall comply with F244.2.3.2....