PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
Search Results "Guest Room (Transient Lodging)"
Commonly Searched Documents
-
Plumbing/Restrooms
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Re: 216 Signs
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
Types of Interpreting
There are several types of interpreting, and it is important to ask individuals which type they need. You may need to provide multiple types of interpreters for multiple individuals....
-
Accessible Route to Exercise Machines and Equipment
raised concerns that the requirement to provide accessible routes to serve accessible exercise machines and equipment will be difficult for some facilities to provide, especially some transient...
-
608.4 Seats (Exception)
. * * * A folding seat shall be provided in roll-in type showers required in transient lodging guest rooms with mobility features complying with 806.2 and in roll-in type showers provided...
-
Where Platform Lifts are Permitted [§206.7]
public use raised courtroom stations, such as jury boxes, witness stands, judges’ benches, clerks stations and depressed areas such as the well of the court levels within transient...
-
PLACE OF PUBLIC ACCOMMODATION
For purposes of this code, a facility is a "place of lodging" if it is (i) An inn, hotel, or motel; or (ii) A facility that (A) Provides guest rooms for sleeping for stays that...
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
703.5.5 Character Height
703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
A4.30.5 Finish and Contrast
An eggshell finish (11 to 19 degree gloss on 60 degree glossimeter) is recommended. Research indicates that signs are more legible for persons with low vision when characters...
-
4.30.5* Finish and Contrast
4.30.5* Finish and Contrast. The characters and background of signs shall be eggshell, matte, or other non-glare finish. Characters and symbols shall contrast with their background...
-
4.30.3* COLOR CONTRAST
Characters and symbols shall contrast with their background - either light characters on a dark background or dark characters on a light background.
-
11B-703.5.5 Character height
11B-703.5.5 Character height. Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
Birthing Room Bath Tub Accessibility
has two birthing rooms Both rooms have fully accessible toilet rooms and showers Both rooms equipped with a bath tub - used to "ease discomfort" during labor Question are bath...
- Access Board: Sign Scoping
- Takeform Fusion Signage Office/Suite/Room Identification Type G.2
-
Section 36.403 Alterations: Path of Travel (Section-By-Section Analysis and Response to Comments)
Areas that contain a primary function include, but are not limited to, the customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as...
-
F206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....