route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground Surfaces|_, 11B-403.3, 11B-405.2 _|Slope...
Search Results "Counter Slope"
-
11B-1008.2.3 Water play components
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Angled or rounded nosings or sloped risers help prevent this hazard and provide a smoother transition. Straight risers without nosings are acceptable....
-
F216.13 Trailhead Signs
requirements in 1017.11 require the signs to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and minimum running slope...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-1008.2.3 Water play components
route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground Surfaces|_, 11B-403.3, 11B-405.2 _|Slope...
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Passing Spaces [1016.4]
When passing spaces and resting intervals overlap, the technical requirements for resting intervals apply and the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
11B-606.2 Clear floor space
knee clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter...
-
11B-606.2 Clear floor space
knee clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter...
-
Customizing the readily achievable plan
For example, Business A may have very limited resources and can only create an accessible route inside the store and lower a counter that contains product samples....
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
4.7.5 Sides of Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
4.9.3 Nosings
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
4.9.3 NOSINGS
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
1018.10 Dune Crossings
This section requires handrails complying with 505 of the Architectural Barriers Act Accessibility Guidelines and curbs or barriers to be provided where the slope of a beach access route...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.159(c)(3) Ramp threshold
Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Guest Bathrooms
located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground. 806.2.4.1 Vanity Counter...