High-top vans, which disabled people or transportation services often use, require higher clearances in parking garages than automobiles....
Search Results "Bathtub Clearance"
Commonly Searched Documents
-
A4.6.3 PARKING SPACES
-
11B-224.2.2 More than fifty guest room facilities
ETA considers the ADA requirement for rooms without roll-in showers to be a recognition that some individuals with mobility impairments actually prefer an accessible bathtub or transfer-type...
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
Recessed Lavatories
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
-
References:
“Clearance Space Envelopes of Wheeled Mobility Device Users for Computer Workstations”. Proceedings of the Human Factors and Ergonomics Society Annual Meeting 2012....
-
Conclusions
Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Recessed Objects
Elements, such as wheelchair accessible drinking fountains, must provide a knee clearance of at least 27”....
-
R210.3 Shared Use Paths
The AASHTO Guide recommends 10 feet vertical clearance along shared use paths, and 8 feet minimum vertical clearance in constrained areas....
-
Floor and Ground Surfaces
apply to: interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances...
-
9.2.2(6)
., one with a water closet, a lavatory, and a bathtub or shower). (f) if only half baths are provided, at least one half bath. (g) carports, garages or parking spaces....
-
Birthing Room Bath Tub Accessibility
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 11B-603 (Toilet and Bathing Rooms) through 11B-610 (Seats)....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....