A transfer surface shall be provided and shall comply with M302.2....
Search Results "Transfer Surface Height"
-
M302.2 Transfer Surface
-
M302.2 Transfer Surface
A transfer surface shall be provided and shall comply with M302.2....
-
Seat width and depth
Seat width and depth: ADA-ABA currently requires a minimum entry point of 24 inches for transfer steps in play (Section 1008.3.1.1) [7] and pool areas (Section 1009.4.5) [7]. ...
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
Analysis of Transfer Surface Dimensions Based on Wheeled Mobility User Anthropometry
Access Board RE: Analysis of Transfer Surface Dimensions Based on Wheeled Mobility User Anthropometry...
-
5.2.2.2 Transfer Surface Depth
5.2.2.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
5.2.2.1 Transfer Surface Width
5.2.2.1 Transfer Surface Width. The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. ...
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
Tread Surface: ADA Standard Section 504.4
Section 504.4 covers the current ADA Standards for the tread surfaces on stairways.
-
Adjustable Height Range Considered
The technical criteria allow the height of transfer surfaces to be either fixed or adjustable within the 17 inches minimum and 19 inches maximum range....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1....
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
Extended Floor or Ground Surface: ADA Standard Section 405.9.1
Section 405.9.1 covers the current ADA Standards for extended floor or ground surface of the ramp run or landing.
- Steelcase Series 5 Height-Adjustable Work Surface