The slopes of trails shall comply with 1017.7....
Search Results "Slope"
-
1017.7 Slopes
-
1017.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
1018.7 Slopes
The slopes of beach access routes shall comply with 1018.7....
-
1018.8.2 Slope
Resting intervals shall have a slope not steeper than 1:48 in any direction....
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided....
-
11.1 Q. Under the individual building test, how is the second step of the test performed, which involves measuring the slope of the finished grade between the entrance and applicable arrival points?
The slope is measured at ground level from the entrance to the top of the pavement of all vehicular and pedestrian arrival points within 50 feet of the planned entrance, or, if there are...
-
11.2 Q. Under the individual building test, at what point of the planned entrance is the measurement taken?
A. On a horizontal plane, the center of each individual doorway should be the point of measurement when measuring to an arrival point, whether the doorway is an entrance door to the...
-
11.3 Q. The site analysis test calls for a calculation of the percentage of the buildable areas having slopes of less than 10 percent. What is the definition of buildable areas?
A. The buildable area is any area of the lot or site where a building can be located in compliance with applicable codes and zoning regulations.
-
12.1 Q...How is the individual building test performed for additional stories, to determine if those stories must also be treated as ground floors?
A. For purposes of determining whether a non-elevator building has more than one ground floor, the point of measurement for additional ground floors, after the first ground floor has...
-
12.2 Q. What happens if a builder deliberately manipulates the grade so that a second story, which also might have been treated as a ground floor, requires steps?
A. Deliberate manipulation of the height of the finished floor level to avoid the requirements of the Fair Housing Act would serve as a basis for the Department to determine that...
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
Clear Deck Space: ADA Standard Section 1009.2.3
The clear deck space shall have a slope not steeper than 1:48....
-
1991 / 1994 ADA Standards - Plan Review Tool - Slopes
1991 / 1994 ADA Standards - Plan Review Tool - Slopes Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Slopes" (354 KB) * * * * * * *...
-
4.3.3 Slope
The slope of tent pads and tent platforms shall not exceed 1:48 (2 percent) in any direction. Exception. ...
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
B1. Slope
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
B2. Slope
Is the vehicle space relatively level (2% maximum slope in all directions)? Yes _____ No _____...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
The slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance exceed 15 percent...
-
TEST NO. 2 – SITE ANALYSIS TEST
Calculate the percentage of the total buildable area of the undisturbed site with a natural grade less than 10-percent slope....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites...
-
11B-503.4 Floor and ground surfaces
Exception: Slopes not steeper than 1:48 shall be permitted...