A. DEFINITIONS AND BACKGROUND
-
11B-805.4.3 Turning space
ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, has issued Code Application...
-
11B-805.4.3 Turning space
ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, issued Code Application...
- Rockwood Manufacturing Company 596S Hospital Push Pull Latch 2-3/4" Backset
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
- Easter Seals Kentucky Cardinal Hill
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Bedside Clearance [9.2.2(1)]
Bedside Clearance [9.2.2(1)] Where one bed is provided in a room, maneuvering space at least 36 inches wide is required on both sides of the bed....
-
Question 16
Should the Department develop a general standard that specifies requirements for beds wherever accessible sleeping accommodations are required?...
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The section also requires a means to control at least one source of lighting from the bed, such as bedside lamps, wall switches near the bed, or remote control devices that can be operated...
-
233.4.1
233.4.1 In sleeping rooms with more than 25 beds, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
Dispersion
Comments urged that dispersion should be based on bed count, instead of bed type....
-
6.3(2)
In rooms with 2 beds, it is preferable that this space be located between beds....
- Architectural Builders Hardware Mfg., Inc. 6830 Series Time Out/Reverse Low Profile Hospital Latch
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....