The exception does not require work surfaces to be provided at kitchen counters where a table is provided within the kitchen; an electric outlet is provided within reach of the table; and...
Search Results "Electrical Receptacle"
Commonly Searched Documents
-
804.3 Kitchen Work Surface (Exception)
-
11B-812.1 General
Electric vehicle charging stations (EVCS) shall comply with Section 11B-812 as required by Section 11B-228.3....
-
11B-812.1 General
Electric vehicle charging stations (EVCS) shall comply with Section 11B-812 as required by Section 11B-228.3....
-
11B-233.3.1.2.6.5 Additional requirements.
Electrical receptacles, switches and controls complying with Section 11B-809.12. 8. Faucets complying with Section 11B-809.10.8.6. 9....
-
CAL Green requires x number of EVSE per xxx number of spaces - each on its own 40 amp circuit. Some dual EVSE are on a single 40 amp circuit and split the 40 amp. Does this mean that half of those plugs don't comply with the required number?
RESPONSE: The California Green Code appears to require service panels, sub-panels, and raceway of sufficient capacity to accommodate 40 amp circuits rather than mandating one 40 amp...
-
11B-228.3.2 Minimum number
Where an EV charger can simultaneously charge more than one vehicle, the number of EV chargers provided shall be considered equivalent to the number of electric vehicles that can be simultaneously...
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve. Changes in level, slopes...
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) shall not be required.
-
Guest Rooms
Beds. Bed heights for accessible rooms should be between 17-23 inches above the floor Do not have border frame which prevents the wheelchair from being directly...
-
Machinery Spaces: ADA Standard Section 203.5
Section 203.5 covers scoping requirements of general exceptions for machinery spaces in the most current ADA Standards.
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
11B-228.3.1 General
Where electric vehicle charging stations (EVCS) are provided, EVCS shall be provided in accordance with Section 11B-228.3....
-
11B-228.3.1 General
Where electric vehicle charging stations (EVCS) are provided, EVCS shall be provided in accordance with Section 11B-228.3....
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4. Where EVCS...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle.
-
11B-812.6 Vehicle spaces
Vehicle spaces serving van accessible, standard accessible, ambulatory and drive-up EVCS shall be 216 inches (5486 mm) long minimum and shall comply with Sections 11B-812.6.1 through...
-
11B-812.10.2 Operable parts
Operable parts and charging cord storage shall comply with Section 11B-309.
-
11B-812.10.2 Operable parts
Operable parts and charging cord storage shall comply with Section 11B-309.