Section 206.5.1 covers scoping requirements in the most current ADA Standards for doors, doorways, and gates at entrances.
Search Results "Door Height"
Commonly Searched Documents
-
Entrances: ADA Standard Section 206.5.1
-
Rooms and Spaces: ADA Standard Section 206.5.2
Section 206.5.2 covers scoping requirements in the most current ADA Standards for accessible routes to rooms and spaces.
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
Seat Height
Commenters noted that this specification should be clarified as applying to the height as measured at the top of the seat surface. Response....
-
Pool Stairs: ADA Standard Section 1009.6.1
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:...
-
Pressalit Care Lift for Manually Height Adjustable Worktop
Requires the Premium User plan or above. (Login or upgrade your account!)
-
3.3.16 Door Use
3.3.16 Door Use A total of 144 WhMD users completed door use tasks for at least one of the doors....
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
Highest and Lowest Heights Obtained
For all of the minimum height transfers, the 75th and 95th percentiles were at the minimum transfer height possible with the station (10 inches)....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.12 Automatic Doors and Power-Assisted Doors
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
A4.13.12 AUTOMATIC DOORS AND POWER-ASSISTED DOORS
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
4.1.3 Adjustable Height Chairs with and without Footplates
4.1.3 Adjustable Height Chairs with and without Footplates Patients seated in adjustable height examination chairs typically rest their feet on the floor or on a footplate or have their...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
404 Doors, Doorways, and Gates
Changes made to the requirements for manually operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage...
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....