Search Results "Character Spacing (VMS)"
Commonly Searched Documents
-
T702 Signs
-
T702.2 Character Style
Characters shall be displayed in sans serif fonts and shall not use italic, oblique, script, highly decorative, or other unusual forms....
-
Type: ADA Standard Section 407.4.7.1.1
Section 407.4.7.1.1 covers the current ADA Standards for type of designations and indicators required on elevator car control button.
-
T702.3 Character Proportions
Characters shall use fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
Stroke Thickness: ADA Standard Section 703.2.6
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3....
-
11B-703.5.10 Format
Text shall be in a horizontal format.
-
11B-703.2.9 Format
Text shall be in a horizontal format.
-
A4.30.4 RAISED OR INDENTED CHARACTERS OR SYMBOLS
Braille characters can be used in addition to standard alphabet characters and numbers....
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both....
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both....
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5.
-
11B-703.8 Variable message signs
[See subsections ...]
-
11B-703.8 Variable message signs
11B-703.8 Variable message signs.
-
11B-703.8 Variable message signs
[See subsections ...]
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised characters must be 2 inches high. Braille characters are often located below raised characters, although the location is not specified in ADAAG....
-
703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both....
-
R410.3 Case
Characters shall be uppercase or lowercase or a combination of both....
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms....
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....