A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
Search Results "Seating Space"
-
11B-809.10.5.1 Clear floor space
-
Single-User Toilet Rooms: Side Transfer Space
Single-User Toilet Rooms: Side Transfer Space These drawings illustrate the space requirements for a single-user toilet room with a single plumbing wall....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
1011.2 Clear Ground Space
A clear ground space complying with 1011.2 shall be provided at outdoor constructed features....
-
Clear Floor or Ground Space
Clear Floor or Ground Space Clear floor space - also known as ground space - provides unobstructed room to accommodate a single stationary wheelchair and its occupant at a play component...
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
11B-806.2.2 Exterior spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided....
- Figure 502.3 Parking Space Access Aisle – Drawing from the U.S. Access Board
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-1005.5 Turning space
At least one turning space complying with Section 11B-304.3 shall be provided on fishing piers and platforms....
-
11B-1005.5 Turning space
At least one turning space complying with Section 11B-304.3 shall be provided on fishing piers and platforms....
-
11B-1005.5 Turning space
At least one turning space complying with Section 11B-304.3 shall be provided on fishing piers and platforms....
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided. [ECTCR UFAS 4.18.3]...
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
Dispersion Requirements
These requirements have been revised and relocated to the scoping section for wheelchair spaces at section 221....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum. FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE...
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....