Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
Search Results "Patient in Seated Position"
-
607.2 Clearance
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
(1) Adjustability: Minimum High Transfer Height
Seat heights for males were typically higher than for females....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
805.2 Turning Space
Turning space complying with 304 shall be provided within the room.
-
805.2 Turning Space
Turning space complying with 304 shall be provided within the room.
-
805.2 Turning Space
805.2 Turning Space. Turning space complying with 304 shall be provided within the room.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
M301.4.1 Clearance in Base
[See subsections ...]
-
§ 38.125(d)(1) Requirements
All intercity rail cars required to be accessible by §§38.111 (a) and (e) of this subpart shall provide at least one, but not more than two, mobility aid seating location(s) complying with...
-
Sec.36.308(b) New construction and alterations
The provision and location of wheelchair seating spaces in newly constructed or altered assembly areas shall be governed by the standards for new construction and alterations in subpart...
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
Transfer Protocols
Participant selects which grab bars to use (2.75in or 6in) and seat width Primary measures: maximum/minimum heights attained, preferred seat width, WMD angle and position...
-
Section 35.151(g) Assembly Areas (Section-by-Section Analysis)
The sale of any seats in the covered area requires removal of the platform, thereby eliminating some of the required wheelchair seating locations. ...
-
Minimum Requirement
.); where fixed seating is provided and where there may be an audio-amplification system....
-
Section 35.151(g) Assembly areas (Section-by-Section Analysis)
These platforms cover groups of conventional seats and are used to provide groups of wheelchair seats and companion seats....
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...