Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
Search Results "Direction of Travel"
Commonly Searched Documents
-
Egress Signage
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
R308.1.2.2 Slope
Boarding platforms shall not exceed a slope of 2 percent in any direction....
-
11B-411.2.1.2.4 Display screen
function button, the display screen shall display information on the location and use of the star (*) and minus sign (-) buttons, user input confirmation, elevator assignment characters, direction...
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 (2 percent) in any direction....
-
IV. CONCLUSION
The Clerk of Court is directed to close the motions, Docs. 79 and 96. SO ORDERED. Dated: March 5, 2019 New York, New York ___________________ Edgardo Ramos, U.S.D.J....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
CLEARANCES AT DOORWAYS WITHOUT DOORS ORÂ GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS Â MINIMUM MANEUVERING CLEARANCE Approach direction...
-
11B-404.3 Automatic and power-assisted doors and gates
using wheelchairs because holding the door open with one hand requires the user to let go of one wheel – not enough control remains to prevent the chair from twisting out of the intended direction...
-
1124B
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 inch (12.7 mm) wide in one direction (see Figure 11B-7E)....
-
Re: 405 Ramps
A ramp with a direction change requires a 60" x 60" minimum intermediate landing, which isn't just a turning space but also a place for stopping to allow for a turn....
-
810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
Question 10
entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door, depending on direction...
-
A5. Accessible Parking Spaces
Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions?...
-
Can handrail extensions wrap or turn?
Otherwise, handrail extensions must be in same direction as the ramp run....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Safe Harbors
The term "Safe Harbor" does not appear in CBC, but a similar provision is included in Exception 2 at Section 11B-202.4, excerpted here: 11B-202.4 Path of travel requirements in alterations...
-
Section 36.208(b) (Section-By-Section Analysis and Response to Comments)
Paragraph (b) of this section explains that a "direct threat'' is a significant risk to the health or safety of others that cannot be eliminated by a modification of policies, practices,...
-
Wheelchair Spaces
This was done to limit the inconvenience to those occupying wheelchair spaces who would otherwise have to move, possibly from the space or row entirely, to accommodate others traveling to...
- TechnoGym® - Radiant Inclusive Commercial Fitness System
- PlayLSI Elevated Sand Table Play Component
- Touch Mapper Tactile Street Maps