A minimum of 36 by 48 inches of clear ground space must be provided near a bench, with one side of the clear space adjoining an ORAR or trail as applicable....
Search Results "Clear Opening"
Commonly Searched Documents
-
Benches [1011.2]
-
Additional benefits of water closet clearance standards
clearance provisions will have nonmonetized benefits that promote equal access and equal opportunity for individuals with disabilities, and will further the ADA’ s purpose of providing ‘‘a clear...
-
Additional benefits of water closet clearance standards
clearance provisions will have non-monetized benefits that promote equal access and equal opportunity for individuals with disabilities, and will further the ADA's purpose of providing ‘‘a clear...
-
§ 38.125(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
Technical difficulty and readily achievable
A small business has an exterior door opening that is only 26 inches wide....
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
The opening for dispensing the water is called a water spout....
- NABCO GT300 & GT8300 Overhead Concealed Low-Energy Swing Door Operator
- Inpro Corporation JointMaster® AR Series Seal Expansion Joint Systems
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
Technical Memorandum TM 2013-17 Water Closet Clearance - Overlap
TM 2013-17 Water Closet Clearances - Overlap Effective Date: June 1, 2013 2012 TAS Reference: 604.3.2 Based on TAS 106.3 and the application of terms and definitions...
-
L. Lavatory
L. Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear...
-
8.2 Reading and Study Areas
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and...
-
8.2 READING AND STUDY AREAS
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and study...
-
11B-604.3.1 Size
11B-604.3.1 Size. Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
Automatic Door Break Out Openings
Automatic Door Break Out Openings. The 1991 Standards do not contain any technical requirement for automatic door break out openings....
-
11B-226.4 Baby changing tables
This has been generally understood to include the technical requirements for accessible routes, clear floor space, reach ranges, knee and toe space, worksurface heights, operable parts and...
-
1007.7.5 Openness
1007.7.5 Openness. The exterior area for assisted rescue shall be open to the outside air....
-
Other Requirements in the ADA Standards
Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....