Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
Search Results "Character Width (VMS)"
-
11B-703.3.2 Position
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
-
11B-405.7.2.1
Advisory 11B-405.7.2.1 Top landing width. Handrail extensions are not permitted to obstruct required clear landing dimensions except as allowed by the exception to Section 11B-307.2....
-
1009.9 Signage
Signage shall comply with Chapter 11A, Section 1143A and Chapter 11B, Section 11B-703.5 as applicable, requirements for visual characters and include the International Symbol of Accessibility...
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
T702.5 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements....
-
703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements. ...
-
D. Signage
Existing tactile signage will be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character...
-
802.1.5 Overlap
The term "circulation paths" used in 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
11B-411.2.1.2.1 Keypads
Characters and symbols shall be centered on the corresponding button. The number five key shall have a single raised dot....
-
11B-411.2.1.2.1 Keypads
Characters and symbols shall be centered on the corresponding button. The number five key shall have a single raised dot....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-802.1.5 Overlap
The term "circulation paths" used in 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
802.1.5 Overlap
The term "circulation paths" used in 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
802.1.5 Overlap
The term "circulation paths" used in Section 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
11B-802.1.5 Overlap
The term "circulation paths" used in 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
703.6.1 Pictogram Field
Characters and braille shall not be located in the pictogram field....
-
R410.7 Height from Finish Surface
Visual characters shall be 1.0 m (3.25 ft) minimum above the finish surface....