Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5....
Search Results "Shall"
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
406.2.2 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm)....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Platform and Vehicle Floor Coordination: ADA Standard Section 810.5.3
Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable requirements of 36 CFR Part 1192....
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
11B-242.2 Swimming pools
At least two accessible means of entry shall be provided for swimming pools....
-
11B-219.3 Receivers
The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two....
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
11B-242.2 Swimming pools
At least two accessible means of entry shall be provided for swimming pools....
-
11B-219.3 Receivers
The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two....
-
Elevator Door Requirements: ADA Standard Section 407.3
Section 407.3 covers the current ADA Standards for elevator door requirements.
-
Number and Location: ADA Standard Section 221.2.1
Section 221.2.1 covers scoping requirements in the current ADA Standards for the number and location of wheelchair spaces.
-
General: ADA Standard Section 239.1
Section 239.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for miniature golf facilities.
-
General: ADA Standard Section 603.1
Section 603.1 of the ADA Standards covers information in the current ADA Standards for toilet and bathing rooms.
-
Leveling: ADA Standard Section 408.4.4
Section 408.4.4 covers the ADA Standards for the self-leveling feature in limited-use/limited-application elevators.
-
Wheelchair Accessible Compartments: ADA Standard Section 604.8.1
Section 604.8.1 covers the current ADA Standards for wheelchair accessible compartments.
-
Controls: ADA Standard Section 804.6.5.3
Ovens shall have controls on front panels....
-
Illumination: ADA Standard Section 408.4.5
Section 408.4.5 covers the current ADA Standards for the illumination of the elevator car in limited-use/limited-application elevators.
-
General: ADA Standard Section 1003.1
Recreational boating facilities shall comply with 1003....