The Department gave careful consideration to the costs and benefits of its adoption of the standards relating to water closet clearances in single-user toilet rooms. The primary...
Search Results "Ground Floor Exit"
-
Water Closet Clearances
-
§ 38.53(d) Coordination with boarding platform
(d) Coordination with boarding platform—
-
Section 810.5.3
Section 810.5.3 This section concerns coordination between rail platforms and rail vehicles. The Department is adding language from the former §10.3.1 (9) (Exception 2), which...
-
14) Carpet and carpet tile
14) Carpet and carpet tile ADAAG: Same standards for carpet and carpet tile: maximum pile height of 1/2" (§4.5.3). UFAS: Carpet must have maximum pile height of 1/2". Carpet...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
10.2.1(2)
or replaced bus shelters shall be installed or positioned so as to permit a wheelchair or mobility aid user to enter from the public way and to reach a location, having a minimum clear floor...
- Landscape Forms Inc. Sort Recycling Units
-
11B-809.10.6.3 Clearance
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Amendments increase clear floor...
-
§ 38.73(d)(1) Requirements
the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor...
- 305.3 Trash Can Clear Floor Space
- 604.3.1 Water Closet Clear Floor Space
-
Recessed Lavatories
(If the clear floor space at the lavatory is obstructed on both sides more than 2 feet then it must be at least 36 inches wide instead of 30 inches.)...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
1134A.8, Item 5
Finished floor. The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
Finished floor. The finished floor beneath the lavatory shall be extended to the wall....
-
§ 38.53(d)(1) Requirements
coordinated with the boarding platform design such that the horizontal gap between each vehicle door at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Signage
Mounting height shall be 60 in (1525 mm) above the finish floor to the centerline of the sign....