Faucets, including hand-operated metering faucets, must remain open for at least 10 seconds (606.4). The proposed rule referred to these as "self-closing" faucets....
Search Results "Break Out Opening"
-
Self-Closing Faucets
-
611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 36 inches (915 mm) maximum above the finish floor....
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting intervals...
-
D4. Door Clearance
If No, leave the door propped open, install a power operator, or look for another accessible entrance. Yes _____ No _____...
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close....
-
4.3.11.1(2)
Openings to the interior of the building located within 20 feet (6 m) of the area of rescue assistance shall be protected with fire assemblies having a three-fourths hour fire protection...
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close....
-
§ 38.101(b)
(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform...
-
§ 38.157(b)
(b) The vehicle doorway shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the pathway to the door for a distance of 3 feet (915...
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
Guidelines for Requirement 3
(2) For doors within individual dwelling units, the Department has retained, in the final Guidelines, the design specification that a door with a clear opening of at least 32 inches...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
10.3.1(7)*
Accessible fare collection devices shall have a minimum clear opening width of 32 in; shall permit passage of a wheelchair; and, where provided, coin or card slots and controls necessary...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Common Problems with Toilet Rooms
some of the most common: Ø The door is too narrow, or there is not enough maneuvering space immediately inside or outside the toilet room door for a person using a wheelchair to open...
-
§382.129(a)
You must carry out these instructions to the greatest extent feasible, consistent with FAA, PHMSA, TSA, or applicable foreign government requirements concerning security, safety, and hazardous...
-
8. Q: What steps should officers follow to communicate effectively with an individual who is blind or visually impaired?
Officers must read out loud in full any documents that a person who is blind or visually impaired needs to sign....
-
H15
Is at least one wide toilet stall provided with an out swinging door, side and rear grab bars, and clear space next to the toilet?...
-
§ 38.159(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
-
Parking
One out of every six accessible spaces must be van-accessible....
-
Minimum Number of Accessible Parking Spaces
provided in each lot 1/8 of Column A* 7/8 of Column A** 1001 and over 20 plus 1 for each 100 over 1000 1/8 of Column A* 7/8 of Column A** * one out...
-
11B-809.8.3 Door maneuvering clearance.
A 39 inch (991 mm) minimum length is allowed at interior doors when a clear opening width of 34 inches (864 mm) minimum is provided....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....